AS NZS 60335.2.58:2018 pdf download.Household and similar electrical appliances- Safety.
3 Terms and definitions
This clause of Part 1 is applicable except as follows.
3.1.4 Addition:
Note I to entry: The rated power Input is the sum of the power inputs of all the individual elements in the appliance that can be on at one time; where there are several such combinations possible, that giving the highest power input is used in determining the rated power input.
3.1.9 Replacement:
normal operation
operation of the appliance under the following conditions
Appliances intended to be connected to a water supply are connected to a water supply having the pressure and temperature specified in the instructions.
If a range of temperatures and pressures is specified in the instructions then the water supply is at the conditions within the range that will give the most unfavourable temperature results. Water inlets intended for cold water only are connected to a source supplying water at a temperature of 15 °C ± 5 °C.
The appliance is filled with the maximum quantity of water for which it is designed, without detergents or rinsing agents. Brush machines are tested with dishes and the dishwasher is loaded with the maximum number of dishes specified in the instructions for use. The dimensions of the dishes are as specified in IEC 60436. Other appliances are tested without dishes.
Batch dishwashers are operated on continuous cycles, each cycle being followed by a rest period of 1 mm. Lids or covers, if any, are left open during the rest period.
Conveyor dishwashers and brush machines are operated continuously.The appliance is operated as follows: appliances with automatic timers or programmers are operated with the programme that will give the most unfavourable temperature results; appliances that have neither an automatic timer nor a programmer are operated in accordance with the instructions for use, but with the controls intended to be set by the  user set at maximum or that setting giving the most unfavourable temperature results.
3.5.101 batch dis hwasher appliance in which the various processes are carried out sequentially on a single load
3.5.102 brush machine appliance in which plates are cleaned by being placed between or held in contact with brushes or similar devices
3.5.103 conveyor (rack or flight) dishwasher appliance in which the various processes, e.g. washing, rinsing etc., are carried out, the load being moved through the various operations automatically
3.8.101 indicated level mark on the appliance to indicate the maximum liquid level for correct operation
4 General requirement This clause of Part 1 is applicable.
5 General conditions for the tests This clause of Part 1 is applicable except as follows.
5.3 Addition: The tests of 22.6 are carried out before the tests of Clause 19.
5.101 Appliances are tested as motor-operated appliances, even if they incorporate a heating element. Appliances incorporating means for heating water, but that may also be operated without the heating elements being energized, are tested without the heating elements energized should this be more unfavourable.
5.102 Appliances, when assembled in combination with or incorporating other appliances, are tested in accordance with the requirements of this standard. The other appliances are operated simultaneously in accordance with the requirements of the relevant standards.
6 Classification This clause of Part 1 is applicable except as follows. 6.1 Replacement: Appliances shall be class I with respect to protection against electric shock. Compliance is checked by inspection and by the relevant tests. 6.2 Replacement: Appliances shall be at least IPX1 with respect to protection against harmful ingress of water. Compliance is checked by inspection and by the relevant tests.
7 Marking and instructions This clause of Part 1 is applicable except as follows. 7.1 Addition: Appliances shall be marked with 一the maximum permissible steam pressure, in kilopascals (kPa); 一the maximum permissible hot water pressure, in kilopascals (kPa); 一the maximum permissible water, steam and hot water temperatures in degrees Celsius. If the reversal of a motor could result in a hazard, the direction of rotation shall be clearly and visibly indicated on the motor. Modification:  The instruction concerning persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge is not applicable. The instruction concerning children playing with the appliance is not applicable.AS NZS 60335.2.58 pdf free download.