SAE J593-2000 pdf download

12-28-2022 comment

SAE J593-2000 pdf download Backup Lamps (Reversing Lamps)
Scope-This SAE Standard provides installation requirements, test procedures, design guidelines, andperformance requirements for backup lamps.
References
2.1 Applicable Publications–The following publications form a part of this specification to the extent specifiedherein. The latest issue of SAE publications shall apply.
SAE PUBLICATIONS-Available from SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001.2.1.1
SAE J567-Lamp Bulb Retention SystemSAE J575-Test Methods and Equipment for Lighting Devices and Components for Use on Vehicles Lessthan 2032 mm in Overall WidthSAE J576-Plastic Materials for Use in Optical Parts such as Lenses and Reflectors of Motor VehicleLighting DevicesSAEJ578Color Specification
SAE J759Lighting ldentification CodeSAE J1330-Photometry Laboratory Accuracy Guidelines
Definitions
3.1Backup Lamp-A lighting device used to provide illumination behind the vehicle and to provide a warningsignal to pedestrians and other drivers when the vehicle is backing up or is about to back up.
3.2 Point of Visibility–Any point on the lens surface which is within an area bounded by the intersection of theens surface with a 25 mm diameter cylinder, the centerline of which passes through the light source centerand is oriented horizontally and parallel with the longitudinal axis of the vehicle.
Lighting ldentification Code-Backup Lamps may be identified by the code “R” in accordance with SAEJ759.
5. Tests
5.1 SAE J575 is a part of this report. The following tests are applicable with modifications as indicated:
5.1 .1 V IBRATION T EST
5.1 .2 M OISTURE T EST
5.1 .3 D UST T EST
5.1 .4 C ORROSION T EST
5.1 .5 P HOTOMETRIC T EST
5.1.5.1 Photometric tests shall be made with the photometer at a distance of at least 3 m from the lamp. The H-V Axis shall be taken as the horizontal line through the light source and parallel with the longitudinal axis of the vehicle.
5.1.5.2 Photometric measurements shall be made with the bulb filament steadily burning.
5.1 .6 W ARPAGE T EST O N D EVICES W ITH P LASTIC C OMPONENTS
5.2 Color Test—SAE J578 is part of this report.
5.3 Materials Test—SAE J576 is part of this report.
6. Requirements
6.1 Performance Requirements—A device when tested in accordance with the test procedures specified in Section 5 shall meet the following requirements:
6.1 .1 V IBRATION —SAE J575
6.1 .2 M OISTURE —SAE J575
6.1 .3 D UST —SAE J575
6.1 .4 C ORROSION —SAE J575
6.1 .5 P HOTOMETRY —SAE J575
6.1.5.1 A single lamp, when used in a two-lamp system, shall be designed to conform to the zone total photometric requirements of Table 1 and its footnotes. The summation of the luminous intensity measurements at the test points in a zone shall be at least the value shown. When two lamps of the same or symmetrically opposite design are used, the photometric readings along the vertical axis and the average of the readings for the same angles left and right of vertical for one lamp may be used to determine compliance with the requirements of Table 1 . If two lamps of differing designs are used, they shall be tested individually, and the photometric values added to determine that the combined units meet twice the zone total candela requirements of Table 1 .

                                           Related Information                                             Download
PS:Thank you for your support!
SAE AS 39029-79-2000 pdf download SAE Standards

SAE AS 39029-79-2000 pdf download

SAE AS 39029-79-2000 pdf download CONTACTS, ELECTRICAL CONNECTOR, PIN, CRIMP REMOVABLE, SHIELDED (FOR MIL-C-28748/9 CONNECTORS) REQUIREMENTS: Dimensions, design characteristics, and configuration: See figure 1 and table I. Tools: See table II. Preparation of samples: Contacts shall be...
Read More
SAE AS 39029-83-2000 pdf download SAE Standards

SAE AS 39029-83-2000 pdf download

SAE AS 39029-83-2000 pdf download CONTACTS, ELECTRICAL CONNECTOR, PIN, CRIMP REMOVABLE (FOR MIL-C-28840 CONNECTORS) REQUIREMENTS: Dimensions, design characteristics, and configuration: See figure 1 and table I. Tools: See table II. Localized finish option: Applicable contacts shall be...
Read More
SAE AS 39029-84-2000 pdf download SAE Standards

SAE AS 39029-84-2000 pdf download

SAE AS 39029-84-2000 pdf download CONTACTS, ELECTRICAL CONNECTOR, SOCKET, CRIMP REMOVABLE (FOR MIL-C-28840 CONNECTORS) This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the Synchros described...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information